Boston Scientific Mustang Balloon Catheter 3 x 80 mm | REF H74939171030870

The Boston Scientific Mustang Balloon Catheter (REF H74939171030870) is a percutaneous transluminal angioplasty (PTA) balloon dilatation catheter featuring a 3 mm balloon diameter and an 80 mm balloon length. Designed for the dilatation of stenoses in peripheral vasculature, the Mustang platform combines a high rated burst pressure with a low-profile balloon to support predictable inflation behavior in challenging anatomy.

Key Features
- Balloon diameter: 3 mm
- Balloon length: 80 mm
- Catheter type: Over-the-wire (OTW) PTA balloon dilatation catheter
- High rated burst pressure designed to support post-dilatation and resistant lesions
- Low-profile balloon for crossability through tight stenoses
- Bi-directional radiopaque markers for fluoroscopic balloon positioning
- Hydrophilic coating on the distal shaft to support trackability
- Guidewire compatibility: Not specified in the located sources
- Usable catheter length: Not specified in the located sources

Clinical Applications
- Percutaneous transluminal angioplasty of stenoses in the peripheral vasculature, including iliac, femoral, ilio-femoral, popliteal, infra-popliteal and renal arteries
- Post-dilatation of balloon-expandable and self-expanding stents in the peripheral vasculature
- Treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae
- Not for use in the coronary or neurovasculature

Product Information
- Brand: Boston Scientific
- Product family: Mustang PTA Balloon Dilatation Catheter
- Category: Peripheral Balloon Catheters
- REF / UPN: H74939171030870
- Balloon size: 3 x 80 mm
- Sterility: Supplied sterile, single-use device
- Packaging configuration: Not specified in the located sources

REF / UPNH74939171030870
Size3 x 80, 80 mm

How It Works

1

Submit Your Request

Tell us what product you need and share a few details.

2

We Match You

We connect your request with the most relevant verified brands.

3

Receive Offers

Relevant supplier options can respond with availability, documentation context, and quote details.

Buyer support

Frequently asked questions about Boston Scientific Mustang Balloon Catheter 3 x 80 mm | REF H74939171030870

Practical answers for procurement teams reviewing this product page.

Include the exact product family, brand preference, REF/UPN code when available, required quantity, destination country, expected delivery timing and documentation expectations.

Yes. If alternatives are acceptable, mention equivalent brands, compatible models, size ranges and any non-negotiable requirements.

Related products are connected through structured catalog data such as brand, category, product family and country assignment.

No. This page supports sourcing and RFQ organization. Buyers must verify regulatory status, clinical suitability and procurement compliance independently.

Specific codes reduce ambiguity and help supplier teams identify product availability, packaging details and documentation faster.

Yes. The workflow is designed for hospitals, clinics, distributors, wholesalers, importers and procurement departments.

Yes. Products can be connected to multiple countries in the admin panel, and buyers can specify destination details in the RFQ form.

The request is stored with contact and procurement details so the sourcing conversation can be reviewed and followed up clearly.

Your request has been captured successfully.